Liu Xin, Qin Yongmin, Ni Wenyan, et al. Development and Application of Paperless Quality Control Management System in Pharmacy Intravenous Admixture Service. [J]. 29(10):10-13(2023)
DOI:
Liu Xin, Qin Yongmin, Ni Wenyan, et al. Development and Application of Paperless Quality Control Management System in Pharmacy Intravenous Admixture Service. [J]. 29(10):10-13(2023) DOI: 10. 13407/ j. cnki. jpp. 1672-108X. 2023. 10. 004.
Development and Application of Paperless Quality Control Management System in Pharmacy Intravenous Admixture Service
Objective: To establish and improve the paperless quality control management system and evaluate its application effect in the pharmacy intravenous admixture service (PIVAS). Methods: Functional features of paperless quality control management system designed and developed in our hospital were introduced
the paperless rate and compliance rate of quality control indicators before and after implementation of the system were compared
and the satisfaction with the system in medical staff was investigated to evaluate the application effects. Results: After the implementation of paperless quality control management system
the paperless rate increased from 3. 55% to 94. 24% (χ 2 = 5
363. 779
P<0. 01)
and various paper costs decreased. The compliance rate of quality control indicators increased from 85. 56%± 1. 92% to 93. 33% ± 1. 92% ( t = 6. 360
P< 0. 01). The overall satisfaction score in the medical staff was (36. 05± 2. 85) points ( out of a total score of 42 points)
and 87. 80% of PIVAS staff were highly satisfied. Conclusion: The application of paperless quality control management system has realized electronic data collection
real-time dynamic monitoring
intelligent warning
and information reminders in quality control management work. PIVAS quality control has shifted from “post-event quality control” to “ pre-event quality control
” achieving full-process quality control management informatization and intelligentization and ensuring medication safety for patients.